Six Unpatched Danfoss AK-SM800A Flaws Could Enable Remote Takeover

Summary
Researchers disclosed six unauthenticated AK-SM800A flaws, including one that enabled root code execution in testing. No fix or CVE IDs are available; researchers say firmware 5.4.0 remains affected, and agencies advise removing management interfaces from the internet.
Key points
- Researchers classify all six flaws as pre-authentication stack-based buffer overflows.
- One flaw in the root-running sm_app enabled remote code execution in testing on firmware 3.3.0; the researchers say it is also present in 5.3.2.
- A separate flaw in sm_fcgi_app crashed the gateway in testing; code execution has not been demonstrated for that flaw.
- Researchers say firmware 5.4.0 does not fix the flaws; BSI said it could not rule out that version being affected.
- No CVE IDs, fixed firmware, or public proof of concept are available. BSI is not aware of active exploitation of these six flaws.
- Researchers and agencies advise removing management interfaces from the internet and routing remote access through a VPN or private network; Strict mode alone is insufficient.
- The article says the new flaws have not been linked to recent refrigeration-controller attacks, which reportedly used exposed panels, default credentials, and older fixed vulnerabilities.
Article Details
- Vulnerability Types
- Stack-based buffer overflow
- Severity
- BSI criticality 3 (Orange), rated for immediate action
- Affected Versions
- Danfoss AK-SM800A firmware 3.3.0
- Danfoss AK-SM800A firmware up to and including 5.3.2
- Danfoss AK-SM800A firmware 5.4.0; researchers say the flaws remain
- Exploitation Status
- not_reported
- Exploit Availability
- claimed_or_private
- Patch Status
- unavailable
- Workarounds
- Remove AK-SM800A management interfaces from direct internet access.
- Route remote access through a VPN, private APN, or internal network.
MITRE ATT&CK
T1078.001 · Default AccountsThe article says attackers in the separate refrigeration-controller campaign abused default credentials; it does not link that activity to the six newly disclosed flaws.T1190 · Exploit Public-Facing ApplicationThe article says attackers in the separate refrigeration-controller campaign abused exposed web panels and older vulnerabilities; it does not link that activity to the six newly disclosed flaws.
CVE
CVE-2025-41450Danfoss · AK-SM 8xxA SeriesEarlier AK-SM800A issues, such as the authentication bypass CVE-2025-41450 and the OS command injection CVE-2025-41451, were addressed in updates released in 2023 and 2025.CVE-2025-41451Danfoss · AK-SM8xxA SeriesEarlier AK-SM800A issues, such as the authentication bypass CVE-2025-41450 and the OS command injection CVE-2025-41451, were addressed in updates released in 2023 and 2025.