Siemens Software Center DLL Vulnerability Exploited in ClickFix Campaign

· Original article ↗

Summary

Attackers exploited a Siemens Software Center DLL-loading flaw in a ClickFix campaign. Siemens released version 4.0.9.8 to fix it and says the malicious package did not come through its distribution channels.

Key points

  • CVE-2026-110936 lets an authenticated local attacker place a malicious DLL where Siemens Software Center will load it, executing code with the program’s privileges.
  • Siemens disclosed the vulnerability on October 15 and later fixed it in version 4.0.9.8; installed copies receive the update automatically when launched.
  • Attackers paired a legitimate, signed Siemens program with malicious DLLs. Siemens said its software was not tampered with and its distribution channels were not used.
  • Siemens links the activity to the Romulus ClickFix operation, which uses fake prompts to persuade users to run malicious commands.
  • Siemens recommends monitoring suspicious behavior and malware-associated folders rather than relying only on file hashes, since the abused Siemens executable is legitimate.
  • Siemens is sharing threat intelligence with authorities and EDR providers; its blog post includes indicators of compromise and infection signs.

Article Details

Vulnerability Types
  • DLL search-order hijacking caused by improper restriction of DLL search locations
Severity
CVSS v4 score: 8.4
Affected Versions
  • Siemens Software Center 3.5.8.7
Exploitation Status
active
Exploit Availability
unknown
Patch Status
available

MITRE ATT&CK

CVE

People

Malware

Vendors

Products

Tools

Related Articles