Ivanti Patches Actively Exploited Connect Secure Zero-Day and Critical Credential Flaws

· Original article ↗

Summary

Ivanti patched an actively exploited Connect Secure authentication bypass and six vulnerabilities in Neurons Patch for Intune and Xtraction. The flaws expose credentials or enable other unauthorized actions; fixes and credential-rotation guidance are available.

Key points

  • CVE-2026-104935 affects Ivanti Connect Secure gateways and lets unauthenticated remote attackers bypass authentication and execute commands. Ivanti confirmed limited exploitation.
  • Affected Connect Secure versions include 22.8R2.4 and earlier, 25.1.2.2 and earlier, and 25.1.1.1 and earlier. Administrators should install fixed releases and run the Integrity Checker Tool.
  • More than 5,500 internet-exposed Connect Secure appliances were being tracked by Shadowserver when BleepingComputer reported the flaw.
  • CVE-2026-109412, rated CVSS 9.9, could let a remotely authenticated attacker access sensitive authentication information in Neurons Patch for Intune. Ivanti deployed a cloud fix and recommends rotating the associated client secret.
  • Five Xtraction vulnerabilities include CVE-2026-106042, rated CVSS 9.9, which can expose EPMM connector credentials to an attacker-controlled server.
  • Xtraction 2026.2.1 and earlier is affected; Ivanti recommends upgrading to 2026.4 and rotating EPMM connector credentials. Other flaws enable file or directory access or modification, trusted-site changes, or SQL password exposure in logs.
  • Ivanti said it was unaware of customers compromised through the Neurons Patch for Intune or Xtraction flaws at disclosure; no public proof-of-concept exploits for those vulnerabilities had been confirmed.

Article Details

Vulnerability Types
  • Authentication bypass
  • Unauthenticated arbitrary command execution
  • Credential exposure
  • Sensitive authentication information access
  • Server-side request redirection to an attacker-controlled server
  • Path traversal enabling arbitrary file reads
  • Unauthorized creation or modification of a trusted site
  • Unauthorized directory modification
  • SQL password exposure in application logs
Severity
CVSS 9.9 for CVE-2026-109412 and CVE-2026-106042; no severity rating stated for the other vulnerabilities.
Affected Versions
  • Connect Secure 22.8R2.4 and earlier
  • Connect Secure 25.1.2.2 and earlier
  • Connect Secure 25.1.1.1 and earlier
  • Xtraction 2026.2.1 and earlier
Exploitation Status
active
Exploit Availability
unknown
Patch Status
available
Workarounds
  • For Neurons Patch for Intune, rotate the client secret associated with the Microsoft Entra ID application registration used for Intune publication.
  • For Xtraction, rotate any EPMM connector credentials used by the application.

MITRE ATT&CK

CVE

Vendors

Products

Tools