Tenda Router Backdoor Enables Admin Access; No Patch Available

· Original article ↗

Summary

CVE-2026-11405 lets a special plaintext password bypass normal login on affected Tenda routers and grant admin access. No patch is available; CERT/CC advises disabling remote web management and limiting LAN exposure.

Key points

  • CERT/CC says CVE-2026-11405 affects specified firmware for the Tenda FH1201, W15E, AC10, AC5, and AC6 V2 routers.
  • After normal MD5-based authentication fails, the firmware checks a plaintext password stored in sys.rzadmin.password.
  • The backdoor accepts any username if the alternate password matches, granting administrator access and a valid web-interface session.
  • CERT/CC says no patch is available; Tenda could not be reached, and BleepingComputer says it has requested comment.
  • Recommended mitigations are to disable remote web management and restrict local network exposure.
  • The issue was reported to CERT/CC by an anonymous researcher; the article says it had no mention of active exploitation.

Article Details

Vulnerability Types
  • Authentication backdoor
  • Authentication bypass
Affected Versions
  • Tenda FH1201: US_FH1201V1.0BR_V1.2.0.14(408)_EN_TD
  • Tenda W15E: US_W15EV1.0br_V15.11.0.5(1068_1567_841)_EN_TDE
  • Tenda AC10: US_AC10V1.0re_V15.03.06.46_multi_TDE01
  • Tenda AC5: US_AC5V1.0RTL_V15.03.06.48_multi_TDE01
  • Tenda AC6 V2: US_AC6V2.0RTL_V15.03.06.51_multi_T
Exploitation Status
not_reported
Exploit Availability
unknown
Patch Status
unavailable
Workarounds
  • Disable the remote web management panel.
  • Restrict local network exposure by changing the default LAN IP address.